Refrigeration Maintenance Services

Commercial Refrigeration Preventative Maintenance Services

Keep Your Refrigeration Equipment At Optimum Performance With Scheduled Analysis, Adjustments, Lubrication, and Cleaning

Maintenance Value Plans Benefits

Peace of Mind

Automatic, periodic inspection, lubricating, adjustment, and cleaning of your refrigeration systems keeps it running at peak efficiency.

Refrigeration Experts At Your Service

A competent, trained, dependable staff of experts to maintain your equipment and its performance.

Preferred MVP Treatment

 
Should you need emergency service, MVP entitles you to TOP-PRIORITY service.

Service You Can Trust

Our skilled experts know their business.  You can rely on our service team and our reputation to give you fast, dependable, and fair service.

Top 10 Reasons for Compressor Failure

01

Lack of Preventive Maintenance Program

A regularly scheduled preventative maintenance program will reduce break-downs and will identify minor problems and mitigate or prevent potential major, expensive problems

02

Key Components Inspection & Replacement

Contactors and Relays which are not operating properly can cause motor burn.  We always check the compressor amp draw against the FLA of the compressor.

02

Key Components Inspection & Replacement

Contactors and Relays which are not operating properly can cause motor burn.  We always check the compressor amp draw against the FLA of the compressor.

03

Dirty Condenser & Evaporator Coils

you cannot properly charge a system or expect operational efficiency with a dirty condenser and/or evaporator coil.

04

Worn Pulleys & Belts

Annually, and sometimes semi-annually depending on equipment duty, new belts should be installed.  The pulley and belt tension should be adjusted at each belt change.

04

Worn Pulleys & Belts

Annually, and sometimes semi-annually depending on equipment duty, new belts should be installed.  The pulley and belt tension should be adjusted at each belt change.

05

Low Refrigerant Charge

This is the worst thing that can happen to a system.  System icing will damage the compressor.  Low refrigerant charge (and identifying and repairing the leak) should be addressed immediately to mitigate compressor damage.

06

Misadjusted Expansion Valve

Poorly adjusted valves will cause liquid flood back thinning the oil and damaging the compressor. 

06

Misadjusted Expansion Valve

Poorly adjusted valves will cause liquid flood back thinning the oil and damaging the compressor. 

07

Liquid & Oil Slug Upon Start-up

A pump down solenoid system or adding a suction line accumulator is the best defense to preventing these conditions.

08

Liquid Floodback

Preventing LF is as simple as cleaning the evaporator, filter and checking the Super Heat.  Compressors are meant to pump vapor.  Any liquid that reaches the cylinders of the compressor is a potential cause for damage.



08

Liquid Floodback

Preventing LF is as simple as cleaning the evaporator, filter and checking the Super Heat.  Compressors are meant to pump vapor.  Any liquid that reaches the cylinders of the compressor is a potential cause for damage.



09

Safety Controls

Making sure that your low pressure switch doesn’t let your system run into a vacuum.

10

Mismatched Oils & Refrigerants​

Oil is in the compressor and it must be compatible with the refrigerant.  With over 100 refrigerants and basically 3 different oils, it is very likely a mismatch of the oil and refrigerant.



10

Mismatched Oils & Refrigerants

Oil is in the compressor and it must be compatible with the refrigerant.  With over 100 refrigerants and basically 3 different oils, it is very likely a mismatch of the oil and refrigerant.

Service You Can Count On!

Call and ask about our MVP program.